供应正品HONEYWELL霍尼韦尔执行器M7284A1012 产品资料: Temperature influence Operating value Drift based on measured value at standard temperature: ?20°C to standard temperature: ±1,000 ppm/°C max. Standard temperature to 60°C: ±1,000 ppm/°C max. (Humidity: 25% to 80%) Operating time Fluctuation based on measured value at standard temperature: ?20°C to standard temperature: ±10% max. Standard temperature to 60°C: ±10% max. (Humidity: 25% to 80%) Humidity influence Operating value Based on ambient humidity of 65% 25% to 80%: ±5% max. Operating time Based on ambient room humidity 25% to 80%: ±10% max. Influence of input frequency At 45 to 65 Hz Operating value ±5% max. Operating time ±10% max. Note: The error in the operating value and operating time under standard conditions. Applicable standards Conforming standards EN60255-5 and EN60255-6 Installation environment (Pollution Degree 2, Overvoltage Category III) EMC EN61326 Safety standards UL508 Insulation resistance 20 M? min. Between external terminals and case Between input terminals and output 1 terminals Between input terminals and output 2 terminals Between output 1 terminals and output 2 terminals Dielectric strength 2,000 VAC for one minute Between external terminals and case Between input terminals and output 1 terminals Between input terminals and output 2 terminals Between output 1 terminals and output 2 terminals Noise immunity 1,500 V power supply terminal common/normal mode Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time Vibration resistance Frequency 10 to 55 Hz, 0.35-mm single amplitude, acceleration 50 m/s2 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along three axes (up/down, left/right, forward/backward) Degree of protection Terminal section: Finger protection Indicators